High Breaking Capacity 6.35x32mm Time Delay Cylindrical Ceramic Tube Fuse Link 10A 250V 6x30mm Slow Blow For Lighting
Main Features
In accordance with UL 248 -1 / -14.
UL file number JDYX2.E365879
cUL file number JDYX8.E365879
High Breaking Capacity reach 1000A
Compact design
Axial leaded and Cartridge Fuse available
Rated voltage 250VAC
Wide current range 100mA~50A
Customized lead forming/90 degree angle available
Non-Transparent Ceramic Tube, sand inside option available
___________________________________________________________
Download________
Performances
A=250VAC
| P/N | Ampere Rating | Voltage Rating | Breaking Capacity | Agency Approvals | |
| UL | cUL | ||||
| BMT0100A | 100mA | 250V | 35A@250V AC (100mA~1A);
100A@250V AC (1.25A~3.5A);
200A@250V AC (4A~10A).
750A@250V AC (12A~30A).
1000A@250V AC (32A~50A) | ● | ● |
| BMT0160A | 160mA | 250V | ● | ● | |
| BMT0200A | 200mA | 250V | ● | ● | |
| BMT0250A | 250mA | 250V | ● | ● | |
| BMT0300A | 300mA | 250V | ● | ● | |
| BMT0315A | 315mA | 250V | ● | ● | |
| BMT0350A | 350mA | 250V | ● | ● | |
| BMT0400A | 400mA | 250V | ● | ● | |
| BMT0500A | 500mA | 250V | ● | ● | |
| BMT0630A | 630mA | 250V | ● | ● | |
| BMT0750A | 750mA | 250V | ● | ● | |
| BMT0800A | 800mA | 250V | ● | ● | |
| BMT1100A | 1A | 250V | ● | ● | |
| BMT1125A | 1.25A | 250V | ● | ● | |
| BMT1150A | 1.5A | 250V | ● | ● | |
| BMT1160A | 1.6A | 250V | ● | ● | |
| BMT1200A | 2A | 250V | ● | ● | |
| BMT1250A | 2.5A | 250V | ● | ● | |
| BMT1300A | 3A | 250V | ● | ● | |
| BMT1315A | 3.15A | 250V | ● | ● | |
| BMT1350A | 3.5A | 250V | ● | ● | |
| BMT1400A | 4A | 250V | ● | ● | |
| BMT1500A | 5A | 250V | ● | ● | |
| BMT1600A | 6A | 250V | ● | ● | |
| BMT1630A | 6.3A | 250V | ● | ● | |
| BMT1800A | 8A | 250V | ● | ● | |
| BMT2100A | 10A | 250V | ● | ● | |
| BMT2120A | 12A | 250V | ● | ● | |
| BMT2150A | 15A | 250V | ● | ● | |
| BMT2200A | 20A | 250V | ● | ● | |
| BMT2250A | 25A | 250V | ● | ● | |
| BMT2300A | 30A | 250V | ● | ● | |
| BMT2320A | 32A | 250V | ● | ● | |
| BMT2500A | 50A | 250V | ● | ● | |
Product Characteristics
| Lead Pull Strength | 5N for 10±1 Seconds |
| Lead Thrust Strength | 2N for 10±1 Seconds |
| Solder ability | Wave : 260℃,≤3s; Soldering Iron: 350±10℃,≤3s. |
| Soldering Heat Resistance | Wave : 260℃,10s; Soldering Iron: 350℃,5s. |
Electrical Characteristics
| Test Condition | All electrical test is to be conducted with the ambient air at a temperature of 25±5℃. |
| Load capacity | When the fuse loads through 100% of rated current, should blow within 4 hours. |
| Interrupting Rating | Breaking Capacity: 35A at 250V AC (BMT In range 100mA~1A); 100A at 250V AC (BMT In range 1.25A~3.5A); 200A at 250V AC (BMT In range 4A~10A); 750A at 250V AC (BMT In range 12A~30A) 1000A at 250V AC (BMT In range 32A~50A). |
| Rising Temperature Test | When the 100% times of Ampere Rating passes the fuse, after reaching thermal balance , the temperature on the fuse surface rising shall not be higher than 75℃. Note: Rising temperature = the Surface temperature - Ambient temperature. |
Operating Characteristics
| % of Ampere Rating(In) | Blowing Time |
| 100%* In | 4 hours Min |
| 200%* In | 120 sec Max |
Dimension (mm)
Axial leaded